8/6/2023 0 Comments Egg incubator temperature![]() ![]() Press Up or Down button to adjust the lower temperature limit. Press “Set” button to enter the setting of the item.ĭ. How to set up the egg incubator Optimum temperature: 100.5 degrees Fahrenheit Temperature range: 99-102 degrees Fahrenheit Relative humidity, day 1-17: 50-55. Press Up or Down button to select "HS" or "LS".Ĭ. Normally, there is no need to reset the HS and LS values.ī. The temperature setting range has been adapted to the temperature requirements of most eggs during the incubation and hatching. For example, if you would like to set the desired temperature as 40℃, which is not within the temperature setting range, you need to set the upper temperature Limit (HS) to 40☌ or above first so that you can set the desired temperature to 40☌. It means that HS is set as 39.5 ℃ and LS is set as 20. The default temperature setting range of this incubator is 20-39.5 ℃ (68-103℉). The upper temperature limit (HS) and lower temperature limit (LS)are the temperature setting range. Remember, these eggs had been out of the incubator for 48 hours in flats in a case at room temperature. Optimal humidity varies: it should be between 40 to 50 percent for the first 18 days. Upper Temperature Limit (HS) & Lower Temperature Limit (LS) The surface temperature of each egg was between 71 and 73 degrees. The temperature should be kept at 99.5 degrees through-out the incubation. Press “Up” or “Down” button to adjust the temperature reading. Press Up or Down button consecutively to select “CA”.Ĭ. For example, when the machine shows a temperature of 38☌, when the measuring instrument temperature is 39☌, CA should be +1☌, if the machine shows a temperature of 39☌, the measuring instrument shows a temperature of 38☌, CA should be -1☌.ī. Once you have a professional measuring instrument, the temperature can be calibrated if the temperature displayed by the measuring instrument and the machine are inconsistent. When testing the sensor, it is recommended to use a professional measuring instrument. If the temperature reading on the display panel is not precise enough, you can calibrate the readings. Press Up/Down button to adjust the low temperature alarm range.Ĭalibrating Temperature Sensor Reading (CA) Press Set button to enter the setting of the item.ĭ. Egg incubation is done under favorable environmental conditions, possibly by brooding and hatching the egg. Press Up/Down button to select "AL" or “AH”.Ĭ. ![]() Press and hold Set button for 3 seconds.ī. If you think that the alarm value of 1☌ is relatively large and wants to set the alarm to 0.5☌, you can set AL and AH to 0.5 ☌. ![]() That is to say, if the incubator temperature higher than 39☌ or lower than 37☌, the alarm will go off. For example, the desired incubator temperature is set as 38☌ and the factory default value of AL & AH is 1☌. If you need to adjust the alarm values, you can modify the settings in AL/AH. The factory setting of the high temperature and low temperature alarm is 1☌. The machine will sound an alarm when the temperature is over or below the alarm temperature range. Low Temperature Alarm Range (AL) & High Temperature Alarm Range (AH) ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |